Description
The DAS1700 high speed, configurable data acquisition system combines a fast sampling rate, deep memory, and a large touchscreen display. Internal software tools are also provided like the power analysis application and a function editor for complex mathematical calculations on multiple channels.
These recorders feature a 1 µs sampling rate on up to 6 channels simultaneously while the 500 GB internal memory allows for recording over long periods. Data is acquired from 4 measurement board types which include universal input, multiplexed, strain gauge, and high voltage. Optional CAN and LIN inputs further extend the ability of this recorder.
Choose any combination of 3 boards, or add the extension module for up to 6 boards for applications ranging from small sensor signal logging to electrical power analysis.
Features and benefits:
- Fast sampling rate: up to 1 MSa/s (1 μs) on each channel
- Up to 72 channels (with multiplexed board)
- 4 measurement board types; Universal, Multiplexed, Strain Gauge, High Voltage
- Measure up to 1000 VAC with high voltage board
- Temperature measurements supporting thermocouples and Pt100/Pt200/Pt500/Pt1000 sensors
- CAN, LIN options
- GPS and IRIG timing options
- 16-bit resolution with multiplexed and strain gauge boards
- 14-bit resolution with universal and high voltage boards
- 500 GB SSD internal memory (2 TB optional)
- 16 logic input channels
- WiFi monitoring and control (standard USB WiFi dongle required)
- CAT III 1000 V and CAT IV 600 V
- Wide TFT display with 15.6-inch touchscreen
- USB host and LAN
- Battery option (up to 2 hours)
- Free software for control and analysis
- Rugged carrying case included
Consider the 8460 if a built-in printer is necessary.
Base Units | Measurement Boards | |||||
Mainframe | Mainframe | Universal | High Voltage | Multiplexed | Strain Gauge | |
Model | DAS1700 | 8460 | DAS984401000 | DAS916006000 | DAS984402000 | DAS984402500 |
Channels | – | – | 6 | 6 | 12 | 6 |
Maximum Voltage | – | – | ± 500 V or 424 VRMS | ± 1000 V or 1000 VRMS | ± 50 VDC | ± 25 VDC |
RMS Voltage | – | – | √ | √ | – | – |
Resolution | – | – | 14 bit | 14 bit | 16 bit | 16 bit |
Sampling Rate | – | – | 1 MSa/s | 1 MSa/s | 5 kSa/s | 100 kSa/s |
Voltage | – | – | √ | √ | √ | √ |
Current | – | – | √ | √ | √ | – |
Frequency | – | – | √ | √ | – | – |
Thermocouple | – | – | √ | – | √ | √ |
Counter | – | – | √ | √ | – | – |
Power Analysis | – | – | √ | √ | – | – |
PRT Sensor | – | – | – | – | Pt100/Pt200/Pt500/Pt1000 | Pt100/Pt1000 |
Options | Ordering Information | |||||
Mainframe Extension | Optional* | – | ||||
Battery | Optional | – | Base unit must be ordered with at least one measurement board | |||
IRIG | Optional | Optional | ||||
GPS | Optional | Optional | Options are factory installed and must be ordered with base unit. | |||
CAN/LIN | Optional | – | ||||
Printer | – | Standard |