LCR Meters Archives - RN Embedded Solutions https://rnembedded.com/product-category/component-testers/lcr-meters/ Tue, 23 Apr 2024 08:41:54 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 https://rnembedded.com/wp-content/uploads/2024/06/cropped-cropped-Embedded-Solutions-2-removebg-preview-32x32.png LCR Meters Archives - RN Embedded Solutions https://rnembedded.com/product-category/component-testers/lcr-meters/ 32 32 878B https://rnembedded.com/product/878b/ Tue, 02 Apr 2024 08:51:29 +0000 https://rnembedded.com/?post_type=product&p=3515 Model 878B
878B, 879B and 880
40,000 Count Dual Display Handheld LCR Meter
3 yr Warranty

[forminator_form id="4242"]

The post 878B appeared first on RN Embedded Solutions.

]]>
The 878B, 879B, and 880 40,000-count handheld LCR meters measure inductance, capacitance, and resistance quickly and precisely. The 879B and 880 also measures impedance, Theta, DCR, and ESR. Additionally, the 880 offers capabilities typically only found in bench LCR meters such as a 4-terminal configuration, basic measurement accuracy up to 0.1%, test frequencies up to 100 kHz,  selectable test signal levels and measurement rate.

Fast auto ranging and quick measurement configuration such as measurement parameter and test frequency selection make these meters very simple to operate. The meter also includes handy functions such as data hold, Min/Max/Average recording, tolerance sorting, and relative mode.

Measurement data can continuously transfer to a PC via the meter’s mini USB interface, using either the provided data logging software or SCPI commands sent from a custom program.

Features & Benefits

  • 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
  • L, C, R, and Z (879B & 880 only) primary measurements
  • Automatic calculation of secondary parameters D, Q, Theta, ESR (Theta/ESR for 879B &880 only), and DCR (880 only)
  • Accuracy up to 0.1% and selectable test frequencies up to 100 kHz (880 only)
  • Fast auto range design for rapid, easy component measurements
  • Auto detect mode for automatic component type identification and measurement type selection (880 only)
  • Relative mode
  • Visible and audible tolerance mode
  • Backlit display (879B & 880 only)
  • Data Hold and Min/Max/Average recording
  • USB (Virtual COM) interface
  • SCPI compliant commands for remote communication
  • Software for datalogging and front panel emulation available as free download
  • Configurable power-up-states
  • All commonly requested accessories included (880 only)

Applications

  • Passive component troubleshooting
  • Electronic assembly
  • Quality control (component sorting)

Ordering Information:  Models 879B and 880 include a 120 V AC adapter as a standard accessory. To include a 230 V AC adapter, order model 879B-220V or 880-220V. AC adapters are optional accessories for the 878B.

The post 878B appeared first on RN Embedded Solutions.

]]>
879B https://rnembedded.com/product/879b/ Tue, 02 Apr 2024 08:42:36 +0000 https://rnembedded.com/?post_type=product&p=3507 Model 879B
878B, 879B and 880
40,000 Count Dual Display Handheld LCR Meter with ESR
3 yr Warranty

[forminator_form id="4240"]

The post 879B appeared first on RN Embedded Solutions.

]]>
The 878B, 879B, and 880 40,000-count handheld LCR meters measure inductance, capacitance, and resistance quickly and precisely. The 879B and 880 also measures impedance, Theta, DCR, and ESR. Additionally, the 880 offers capabilities typically only found in bench LCR meters such as a 4-terminal configuration, basic measurement accuracy up to 0.1%, test frequencies up to 100 kHz,  selectable test signal levels and measurement rate.

Fast auto ranging and quick measurement configuration such as measurement parameter and test frequency selection make these meters very simple to operate. The meter also includes handy functions such as data hold, Min/Max/Average recording, tolerance sorting, and relative mode.

Measurement data can continuously transfer to a PC via the meter’s mini USB interface, using either the provided data logging software or SCPI commands sent from a custom program.

Features & Benefits

  • 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
  • L, C, R, and Z (879B & 880 only) primary measurements
  • Automatic calculation of secondary parameters D, Q, Theta, ESR (Theta/ESR for 879B &880 only), and DCR (880 only)
  • Accuracy up to 0.1% and selectable test frequencies up to 100 kHz (880 only)
  • Fast auto range design for rapid, easy component measurements
  • Auto detect mode for automatic component type identification and measurement type selection (880 only)
  • Relative mode
  • Visible and audible tolerance mode
  • Backlit display (879B & 880 only)
  • Data Hold and Min/Max/Average recording
  • USB (Virtual COM) interface
  • SCPI compliant commands for remote communication
  • Software for datalogging and front panel emulation available as free download
  • Configurable power-up-states
  • All commonly requested accessories included (880 only)

Applications

  • Passive component troubleshooting
  • Electronic assembly
  • Quality control (component sorting)

Ordering Information:  Models 879B and 880 include a 120 V AC adapter as a standard accessory. To include a 230 V AC adapter, order model 879B-220V or 880-220V. AC adapters are optional accessories for the 878B.

The post 879B appeared first on RN Embedded Solutions.

]]>
880 https://rnembedded.com/product/880/ Tue, 02 Apr 2024 08:32:01 +0000 https://rnembedded.com/?post_type=product&p=3502 Model 880
878B, 879B and 880
Dual Display Handheld 100kHz LCR Meter with ESR
3 yr Warranty

[forminator_form id="4239"]

The post 880 appeared first on RN Embedded Solutions.

]]>
The 878B, 879B, and 880 40,000-count handheld LCR meters measure inductance, capacitance, and resistance quickly and precisely. The 879B and 880 also measures impedance, Theta, DCR, and ESR. Additionally, the 880 offers capabilities typically only found in bench LCR meters such as a 4-terminal configuration, basic measurement accuracy up to 0.1%, test frequencies up to 100 kHz,  selectable test signal levels and measurement rate.

Fast auto ranging and quick measurement configuration such as measurement parameter and test frequency selection make these meters very simple to operate. The meter also includes handy functions such as data hold, Min/Max/Average recording, tolerance sorting, and relative mode.

Measurement data can continuously transfer to a PC via the meter’s mini USB interface, using either the provided data logging software or SCPI commands sent from a custom program.

Features & Benefits

  • 40,000 counts resolution on primary and 10,000 counts resolution on secondary display
  • L, C, R, and Z (879B & 880 only) primary measurements
  • Automatic calculation of secondary parameters D, Q, Theta, ESR (Theta/ESR for 879B &880 only), and DCR (880 only)
  • Accuracy up to 0.1% and selectable test frequencies up to 100 kHz (880 only)
  • Fast auto range design for rapid, easy component measurements
  • Auto detect mode for automatic component type identification and measurement type selection (880 only)
  • Relative mode
  • Visible and audible tolerance mode
  • Backlit display (879B & 880 only)
  • Data Hold and Min/Max/Average recording
  • USB (Virtual COM) interface
  • SCPI compliant commands for remote communication
  • Software for datalogging and front panel emulation available as free download
  • Configurable power-up-states
  • All commonly requested accessories included (880 only)

Applications

  • Passive component troubleshooting
  • Electronic assembly
  • Quality control (component sorting)

Ordering Information:  Models 879B and 880 include a 120 V AC adapter as a standard accessory. To include a 230 V AC adapter, order model 879B-220V or 880-220V. AC adapters are optional accessories for the 878B.

The post 880 appeared first on RN Embedded Solutions.

]]>
891 https://rnembedded.com/product/891/ Tue, 02 Apr 2024 07:08:38 +0000 https://rnembedded.com/?post_type=product&p=3492 Model 891
300kHz Bench LCR Meter
3 yr Warranty

[forminator_form id="4234"]

The post 891 appeared first on RN Embedded Solutions.

]]>
The 891 Bench LCR meter is capable of measuring inductors, capacitors, and resistors at DC or from 20 Hz to 300 kHz. The instrument’s compact 2U half-rack form factor is suitable for the bench or rack mount installation. A large 4.3″ color display with all important parameters and measurements visible on one screen makes this meter easy to operate.

The instrument’s convenient bin sorting function and frequency sweep function enables quick sorting and characterization of components. Standard USB, GPIB, and LAN interfaces enhance your productivity by providing remote control capabilities to perform daily operations in production, quality control, and laboratory environments.

  • Measurement parameters: L, C, R, Z, G, B, Y, D, Q, θ, DCR
  • 0.05% best impedance accuracy
  • Fully adjustable test frequency from 20 Hz to 300 kHz with 4-digit resolution
  • 0.5 Vrms and 1 Vrms selectable test levels
  • Adjustable measurement speed for fast readout or better accuracy
  • 300-point linear and logarithmic sweep function
  • Bin sorting function (9 primary, one secondary, and one out-of-spec bin)
  • Save/recall up to 100 setups (10 internal) including 1000 measurements and screenshots
  • Standard USB (Virtual COM), GPIB, and LAN interface for remote control

The post 891 appeared first on RN Embedded Solutions.

]]>
894 https://rnembedded.com/product/894/ Tue, 02 Apr 2024 06:50:01 +0000 https://rnembedded.com/?post_type=product&p=3484 Model 894
894 and 895 Series
1MHz LCR Meter
3 yr Warranty

[forminator_form id="4233"]

The post 894 appeared first on RN Embedded Solutions.

]]>
The 894 and 895 are high accuracy LCR meters capable of measuring inductance, capacitance, and resistance of components and materials at DC or from 20 Hz to 500 kHz or 1 MHz respectively. These LCR meters provide flexible AC and DC test signal configuration. AC test signal voltage is variable from 5 mVrms to 2 Vrms, the AC current is adjustable up to 66.7 mArms, depending on the AC impedance selected, and a DC bias signal can be added. The vivid 4.3-inch TFT LCD offers a clear view of all measured and setting values along with BIN sorting comparator results and a handy Zoom feature that enlarges the measured values to full screen. With a basic accuracy of 0.05%, auto level control (ALC), open / short / load correction and cable length compensation, these meter are perfect tools for R&D, manufacturing and quality control applications.

Features & Benefits

  • AC test signal voltage adjustable up to 2 Vrms
  • 3 AC current ranges, selectable via 30 ohm, 50 ohm or 100 ohm internal AC impedance. The 30 ohm setting provides up to 66.7 mArms of drive current, sufficient for larger inductors and transformers.
  • Built-in DC bias source adjustable from -5V to +5V / -50 mA to +50 mA
  • Fast measurement speed up to 13 ms/reading to increase manufacturing throughput
  • 201-point programmable list sweep function providing ability to sweep frequency, AC and DC bias voltage/current levels
  • Auto-level control to maintain the measurement signal applied to the DUT at a constant level
  • Test signal voltage and current monitoring
  • BIN comparator function to sort components in up to 10 bin locations
  • 1 meter cable compensation
  • 4-terminal fixture and Kelvin clip test leads included
  • Transformer test function with optional transformer test fixture TL89T1
  • Versatile trigger functionality (internal, external, bus and manual)
  • Standard USB, RS232, LAN, and GPIB (895 only) interface for remote control using SCPI commands

The post 894 appeared first on RN Embedded Solutions.

]]>
895 https://rnembedded.com/product/895/ Tue, 02 Apr 2024 06:25:29 +0000 https://rnembedded.com/?post_type=product&p=3476 Model 895
894 and 895 Series
1MHz LCR Meter
3 yr Warranty

[forminator_form id="4231"]

The post 895 appeared first on RN Embedded Solutions.

]]>
The 894 and 895 are high accuracy LCR meters capable of measuring inductance, capacitance, and resistance of components and materials at DC or from 20 Hz to 500 kHz or 1 MHz respectively. These LCR meters provide flexible AC and DC test signal configuration. AC test signal voltage is variable from 5 mVrms to 2 Vrms, the AC current is adjustable up to 66.7 mArms, depending on the AC impedance selected, and a DC bias signal can be added. The vivid 4.3-inch TFT LCD offers a clear view of all measured and setting values along with BIN sorting comparator results and a handy Zoom feature that enlarges the measured values to full screen. With a basic accuracy of 0.05%, auto level control (ALC), open / short / load correction and cable length compensation, these meter are perfect tools for R&D, manufacturing and quality control applications.

Features & Benefits

  • AC test signal voltage adjustable up to 2 Vrms
  • 3 AC current ranges, selectable via 30 ohm, 50 ohm or 100 ohm internal AC impedance. The 30 ohm setting provides up to 66.7 mArms of drive current, sufficient for larger inductors and transformers.
  • Built-in DC bias source adjustable from -5V to +5V / -50 mA to +50 mA
  • Fast measurement speed up to 13 ms/reading to increase manufacturing throughput
  • 201-point programmable list sweep function providing ability to sweep frequency, AC and DC bias voltage/current levels
  • Auto-level control to maintain the measurement signal applied to the DUT at a constant level
  • Test signal voltage and current monitoring
  • BIN comparator function to sort components in up to 10 bin locations
  • 1 meter cable compensation
  • 4-terminal fixture and Kelvin clip test leads included
  • Transformer test function with optional transformer test fixture TL89T1
  • Versatile trigger functionality (internal, external, bus and manual)
  • Standard USB, RS232, LAN, and GPIB (895 only) interface for remote control using SCPI commands